Documentation
Getting Started
Installation and Access
Network Configuration
Verification and Maintenance
The Platform Does Not Show the Device, or Sites Cannot Reach Each Other
Two kinds of problem: the gateway cannot get onto the platform, or devices are online but cannot reach each other.
Decide which kind you have first, then work through the items.
A. The platform does not show the device
- 启用(Enable) is checked in EasyTier
- The startup method is web 配置(Web configuration)
- The address format is
udp://easytier.gshelp.xyz:22020/account name - The account name matches the one registered on the platform exactly, including case
- Wait 1–2 minutes, then refresh the page
If the format and the account name are both right and it still does not come online, see Connecting the gateway to the platform.
B. Devices are online but cannot reach each other
| Possible cause | How to confirm | Fix |
|---|---|---|
| The subnet proxy is not configured | Open the device's 编辑(Edit) → 常规配置(General configuration) and check the CIDR | Configure it following Configuring a subnet proxy |
| The two sites use the same subnet | Compare both sides' LAN subnets | Change one side's LAN subnet, then reconfigure the subnet proxy |
| Access control has only one direction selected | Check whether both directions are selected | Select both directions |
| The bypass router has no endpoint gateway set | Is the endpoint gateway the gateway's LAN port IP? | Change the endpoint gateway, or add a static route on the upstream router |
| The local machine's firewall is blocking | Have the peer ping this computer | Disable the firewall temporarily and try again |
The symptom of repeating subnets
Every device is online and the tunnel looks healthy, yet nothing is reachable. When you hit this, suspect repeating subnets first.
What you should see when done
- The member device status is 在线(Online).
- Ping works in both directions.
One table to rule them all
| Symptom | Confirm first | Then |
|---|---|---|
| The platform does not see the device at all | Whether EasyTier is enabled | Re-enter the address as in Step 3 |
| The device is visible but cannot be added to the network | Whether the device is 在线(Online) | Go back to the gateway and check its networking status |
| It can be added to the network but ping fails | Whether both sides use the same subnet | Change the subnet and reconfigure the subnet proxy |
| Ping works but the business system does not open | Whether access control covers both directions | Select both directions |
| Only some devices are unreachable | The subnet the subnet proxy advertises | Add the missing subnet |
Next → Frequently asked questions
Was this page helpful?A one-line note helps us make these steps more accurate.