Screen​

The large screen is black​

  1. First check whether the terminal power light is on
  2. Then check whether the large screen's input source is switched to the matching port
  3. On the control client, check whether this terminal is online

Only part of the picture appears​

This is usually a mismatch between the output resolution and the video wall layout. Check it under System Settings → Display.

The picture is blurry or soft​

Check cables and connectors. HDMI attenuates over long runs; use fiber HDMI or an extender instead.

Signal​

A signal was added but is not in the list​

Refresh the signal list. For camera-type signals, also confirm the access password and stream address.

Video plays but there is no sound​

Check the control client volume, the system volume, and whether the amplifier is muted. All three layers need checking.

Control​

A control-panel button does nothing​

First ping the control module IP, then check whether the port and commands match the vendor's protocol.

After switching scenes the old picture is still shown​

The signal source itself did not refresh. Click the scene again or restart the signal source.

System​

The license is reported as invalid​

Check whether the system time is correct; an incorrect time causes validation to fail.

The control client cannot connect to the terminal​

Confirm that both are on the same subnet, that the firewall allows the connection, and that the terminal is not occupied by another control client.